WM2000TA 2 ch Temperature/Voltage Measurement Unit

Wireless Data Logger
AirLogger™ WM2000 Series

  • A single unit can perform temperature/voltage measurement on 2 channels.
  • Small but with superior environmental resistance (operating temperature, waterproof/dust-proof performance, vibration resistance).
  • One PC can be connected to as many as 100 measurement units (200 channels).
  • Enables measurement on rotating/moving objects and in enclosed spaces, which has been difficult with conventional products, and significantly reduces wiring work.
wm2000ta

Measurement Targets

Basic When each voltage output sensor is connected
Temperature Voltage Strain Illumination Pressure Air flow Current Other

Main Specifications

Measurement ch/unit 2 ch
External dimensions 54.5 × 45 × 17.5(mm)
Weight 36 g (including battery)
Communication frequency 2.4 GHz wireless communication
Communication distance Max. 30 m
Measurement interval 100 ms, 200 ms, 500 ms, 1 sec, 2 sec, 10 sec, 1 min, 5 min, 10 min
Number of simultaneous connections/1 PC communication unit Measurement interval
  • 1 sec or more: Max. 100 units
  • Less than 1 sec: Max. 30 units
  • Mixed: Max. 70 units (Less than 1 sec: 30 + 1 sec or more: 40)
Power supply Lithium primary battery*1
Operating environment range Temperature: -40°C to less than +100°C (Same value when the waterproof attachment is used)
Humidity: 5 to 85% RH, no condensation (When the heat-resistant case is used: Equivalent to 5 min in 300°C environment)
Vibration resistance Equivalent to JIS D 1601 Type 1 Class C
Dust proof/waterproof performance Equivalent to IP54 (When the waterproof attachment is used)
Thermocouple temperature measurement Thermocouple type Type K, Type T, Type J
Measurement range K:−200 to +1300°C, T: -200 to +400°C, J: -200 to +1000°C
Measurement resolution 0.1°C
Voltage measurement Measurement range ±12 V
Measurement range/resolution -100 mV to 100 mV: 10 μV, -1 V to 1 V: 100 μV, -12 V to 12 V: 1 mV
Absolute maximum rating ±15 V
Waterproof attachment Size: 64.5 x 66.1 x 21 (mm) / Material: Polycarbonate
Heat-resistant case (optional) Click here for details on the heat-resistant case

*Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries.

*1 As replacement of lithium batteries that it should be quoted separately.
For transporting only lithium batteries overseas, lithium batteries are subject to UN standards and should be packaged in accordance with UN packaging standards before transportation.
In case of overseas transportation of lithium batteries alone that need to be packaged as dangerous goods.

Other Functions

  • Remaining battery level display function
  • Signal strength display function
  • Sensor disconnection detection function

Features

Real-Time Simultaneous Measurement at a Maximum of 200 Points

By utilizing the advantage of wireless measurement, up to 200 points (100 units) can be monitored simultaneously in real time.

  • *Sampling time can be set for each unit.
  • *Up to 30 units (60 points) when the sampling time is less than 1 sec.

Equipped with Two Functions: Temperature and Voltage Measurement

Temperature or voltage can be measured on each channel, providing flexible measurement in various environments according to the application.

Wider Measurement Targets with Voltage Output Sensors

Various kinds of physical quantities can be measured such as humidity, pressure, wind speed, or illumination by attaching voltage output sensors.

Expansion of Measurement Environment

The measurement area will be extended to diverse environments such as areas near water or high temperature areas using the water-proof attachment or heat-resistant case.

Countries in Which The Product can be Used

Countries in which the product can be used depends on a certification mark, attached to the measurement unit.
For the details of the countries in which the product can be used, refer to “Regulations of Radio Laws.”

Certification mark

Model 1

Countries in which this product can be used: Japan, China, Vietnam, and Thailand

Model 2

Countries in which this product can be used: Japan, China, Vietnam, Thailand, United States, and EU

Model 3

Countries in which this product can be used: Japan, China, Vietnam, Thailand, United States, EU, and Taiwan

Product Lineup

To use this product, the following product is required for transmission control and receiving data.

Standard

Model Description Price
WM2000TA-000-01 (Calibration certificate not included) 2 ch Temperature/Voltage Measurement Unit: 1 unit
Waterproof attachment: 1 unit
Lithium battery* for trial use: 1
Please contact your representative for price
WM2000TA-000-05 (Calibration certificate not included) 2 ch Temperature/Voltage Measurement Unit: 5 units
Waterproof attachment: 5 units
Lithium battery* for trial use: 5
Please contact your representative for price
WM2000TA-000-10 (Calibration certificate not included) 2 ch Temperature/Voltage Measurement Unit: 10 units
Waterproof attachment: 10 units
Lithium battery* for trial use: 10
Please contact your representative for price

*As replacement of lithium batteries that it should be quoted separately.
For transporting only lithium batteries overseas, lithium batteries are subject to UN standards and should be packaged in accordance with UN packaging standards before transportation.
In case of overseas transportation of lithium batteries alone that need to be packaged as dangerous goods.

Options

Model Description Price
A7090-2000-TA Calibration certificate (1 unit)*1 Please contact your representative for price
A7091-2000-TA Off-site recalibration and calibration certificate (1 unit)*1 Please contact your representative for price
A7010-L10-010 Replacement lithium battery*4 : set of 10*2 Please contact your representative for price
A7010-L10-050 Replacement lithium battery*4 : set of 50*2 Please contact your representative for price
A7030-A00-010 Waterproof attachment for replacement: 10 units/set Please contact your representative for price
A7030-B00-001 Heat-resistant case: 1 unit*3 Please contact your representative for price
A7020 Thermocouple Type K: 5 m Please contact your representative for price

*1 The price of the calibration certificate is for one measurement unit. Please order the calibration certificate for the number of measurement units required.

*2 Exclusive for Strain Measurement Unit (WM2000SA), 2 ch Temperature/Voltage Measurement Unit (WM2000TA), and 7 ch Temperature/Voltage Measurement Unit (WM2000TB).

*3 Exclusive for 2 ch Temperature/Voltage Measurement Unit (WM2000TA) and 7 ch Temperature/Voltage Measurement Unit (WM2000TB).

*4 As replacement of lithium batteries that it should be quoted separately.
For transporting only lithium batteries overseas, lithium batteries are subject to UN standards and should be packaged in accordance with UN packaging standards before transportation.
In case of overseas transportation of lithium batteries alone that need to be packaged as dangerous goods.