Electronic/Electric Devices
AirLogger™ allows for measurement of temperature, strain, etc., in housing without having to process the housing in any way.
Installation and measurement can be performed in a short period of time in settings such as quick inspections of facilities.
Comparison Table
Measurement Target | Temperature | Temperature/Voltage | Strain/Stress/ Load cell |
|
---|---|---|---|---|
Product name | ||||
Ch/Max ch | 1 ch/100 ch | 2 ch/200 ch | 7 ch/700 ch | 1 ch/100 ch |
Measurement range | −200~+1300℃ (K Type) |
Temperature: −200 ~ +1300℃ (K Type) | ±20000µST | |
Voltage: ±12V | ||||
Measurement interval | 0.1 s to 10 min | |||
Size | 35 mm, 35 mm, 14.5 mm | 54.5 mm, 45 mm, 17.5 mm | 60.5 mm, 49 mm, 17.5 mm | 54.5 mm, 45 mm, 17.5 mm |
Weight | 20 g | 36 g | 45 g | 36 g |
Communication distance | 10 m | 30 m | ||
Battery | CR2032 | Special battery *1 | ||
Operating temperature range | -15 to 70°C | -40 to 100°C | -30 to 100°C | |
Lost Data Recovery Function | △ *2 | 〇 |
* The max. number of connections can be used when the sampling period is 1 s or longer.
*1 It is also possible to operate the applicable products without using a dedicated battery by using an external power supply cable.
See optional external power supply.
*2 WM1000 will have a simple lost data recovery function.
Features
Enables Measurement of Temperature and Vibration Inside Housing
- AirLogger™ can measure temperatures/vibration in the same conditions as those of the production operation without making holes in the housing.
- You can place the measurement unit inside a chamber such as a temperature test chamber or thermal shock chamber and monitor temperature/vibration from outside the chamber.
Enables collection of data for inspections, predictive maintenance, and preventive maintenance of equipment
- The compact and light measurement unit can be easily attached to equipment.